Live options Telemetry controls This option allows the live pages to be tailored to
the Operators requirements, disabling the option will
remove all telemetry controls from the Live viewing
pages.
Live options Event controls The unit supports an event database which can be
accessed from the Live page, disabling this option
will remove all event controls and will not allow the
Operator to analyse the event database.
Live options Playback controls It is possible from the Live page to review any
recorded images stored on the Digital Sprite,
disabling this option will remove all playback controls
from the Live viewing page.
How to Congure Video Inputs and Standard Record Settings
Each video input can be individually congured. How to enable each input and set the standard
record settings has been briey described in the Quick Start Guide, this section will detail the full
conguration process; camera resolution and le size, camera titles, termination, video colour and
camera fail notication, standard recording settings.
This section is divided into:
Enabling and congure the camera inputs settings
Conguring the standard record settings
To enable/congure camera input settings:
1. Select Cameras -> Camera and Record Set-up
2. It is possible to identify the global camera resolution (common to all video input); the
current option sets the resolution at 704x512.
3. Within the viewing application it is possible to select High, Medium or Low resolution
images, enter the maximum le size for the High, Medium and low settings.
Note: It is possible to select the viewing resolution of the images from the unit, however the unit
always records at the high resolution settings for optimum quality on recorded images.
4. All connected cameras will be automatically enabled, use this screen to check the
enabled inputs are correct.
5. In the corresponding title box enter the camera name for the video source connected to
that input.
6. If the nal destination that the video source is to be connected is the unit then this input
must be terminated, however if the loop through connections on the unit are to be used
then the corresponding input must be un-terminated. To select termination place a tick
in the box adjacent to the video input. To un-terminate remove the tick from the box.
7. By default the unit presumes all enabled inputs are colour video sources. If you are
connecting a monochrome signal to the unit, it is recommended that the input be set for
mono. Place a tick in the corresponding video input.
8. To enable the unit to send notication that the video input does not detect a 1V peak to
peak signal place a tick in the box adjacent to the video input. This will give a camera
fail alarm.
9. Save the conguration by select Save Settings!
Note: The Day, Night and Weekend mode are displayed when the Schedule Record Rate is
enabled in the Schedule menu (this is enabled by default).